Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Front Pediatr ; 11: 1293320, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38046675

RESUMO

Objective: To examine the correlation between specific indicators and the quality of hip joint ultrasound images in infants and determine whether the individual infant suit ultrasound examination for developmental dysplasia of the hip (DDH). Method: We retrospectively selected infants aged 0-6 months, undergone ultrasound imaging of the left hip joint between September 2021 and March 2022 at Shenzhen Children's Hospital. Using the entropy weighting method, weights were assigned to anatomical structures. Moreover, prospective data was collected from infants aged 5-11 months. The left hip joint was imaged, scored and weighted as before. The correlation between the weighted image quality scores and individual indicators were studied, with the last weighted image quality score used as the dependent variable and the individual indicators used as independent variables. A Long-short term memory (LSTM) model was used to fit the data and evaluate its effectiveness. Finally, The randomly selected images were manually measured and compared to measurements made using artificial intelligence (AI). Results: According to the entropy weight method, the weights of each anatomical structure as follows: bony rim point 0.29, lower iliac limb point 0.41, and glenoid labrum 0.30. The final weighted score for ultrasound image quality is calculated by multiplying each score by its respective weight. Infant gender, age, height, and weight were found to be significantly correlated with the final weighted score of image quality (P < 0.05). The LSTM fitting model had a coefficient of determination (R2) of 0.95. The intra-class correlation coefficient (ICC) for the α and ß angles between manual measurement and AI measurement was 0.98 and 0.93, respectively. Conclusion: The quality of ultrasound images for infants can be influenced by the individual indicators (gender, age, height, and weight). The LSTM model showed good fitting efficiency and can help clinicians select whether the individual infant suit ultrasound examination of DDH.

2.
BMC Pediatr ; 23(1): 259, 2023 05 24.
Artigo em Inglês | MEDLINE | ID: mdl-37226143

RESUMO

BACKGROUND: Neurofibromatosis Type 1 (NF1) is a rare genetic disorder characterized with the development of multiple benign tumors on the nerves and skin. CASE PRESENTATION: This report described a neonatal case with a large mass observed on the left side of the maxillofacial and cervical region at birth. Meantime, multiple cafe-au-lait macules (CALMs) were seen on the trunk and both lower extremities. CONCLUSIONS: In this case, the clinical features of the rare NF1 neonate are discussed along with its ultrasound findings.


Assuntos
Neurofibromatose 1 , Humanos , Recém-Nascido , Neurofibromatose 1/diagnóstico , Neurofibromatose 1/diagnóstico por imagem , Feminino , Pescoço/patologia , Face/patologia , Evolução Fatal
3.
J Ultrasound Med ; 42(6): 1235-1248, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36445006

RESUMO

OBJECTIVES: Ultrasound (US) is important for diagnosing infant developmental dysplasia of the hip (DDH). However, the accuracy of the diagnosis depends heavily on expertise. We aimed to develop a novel automatic system (DDHnet) for accurate, fast, and robust diagnosis of DDH. METHODS: An automatic system, DDHnet, was proposed to diagnose DDH by analyzing static ultrasound images. A five-fold cross-validation experiment was conducted using a dataset containing 881 patients to verify the performance of DDHnet. In addition, a blind test was conducted on 209 patients (158 normal and 51 abnormal cases). The feasibility and performance of DDHnet were investigated by embedding it into ultrasound machines at low computational cost. RESULTS: DDHnet obtained reliable measurements and accurate diagnosis predictions. It reported an intra-class correlation coefficient (ICC) on α angle of 0.96 (95% CI: 0.93-0.97), ß angle of 0.97 (95% CI: 0.95-0.98), FHC of 0.98 (95% CI: 0.96-0.99) and PFD of 0.94 (95% CI: 0.90-0.96) in abnormal cases. DDHnet achieved a sensitivity of 90.56%, specificity of 100%, accuracy of 98.64%, positive predictive value (PPV) of 100%, and negative predictive value (NPV) of 98.44% for the diagnosis of DDH. For the measurement task on the US device, DDHnet took only 1.1 seconds to operate and complete, whereas the experienced senior expert required an average 41.4 seconds. CONCLUSIONS: The proposed DDHnet demonstrate state-of-the-art performance for all four indicators of DDH diagnosis. Fast and highly accurate DDH diagnosis is achievable through DDHnet, and is accessible under constrained computational resources.


Assuntos
Displasia do Desenvolvimento do Quadril , Luxação Congênita de Quadril , Lactente , Humanos , Inteligência Artificial , Luxação Congênita de Quadril/diagnóstico por imagem , Ultrassonografia/métodos , Valor Preditivo dos Testes
4.
J Clin Pharm Ther ; 47(12): 2196-2204, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36259502

RESUMO

WHAT IS KNOWN AND OBJECTIVE: Methotrexate (MTX) is an antimetabolic antitumor drug with high individual differences and may lead to severe toxicities in a considerable number of patients. This study aimed to explore the factors influencing major adverse events in patients with primary central nervous system lymphoma treated with high-dose MTX (HD-MTX), which could be useful in clinical practice. METHODS: Fifty-four patients who received 175 courses of MTX at 3-8 g/m2 between January 2015 and December 2016 were enrolled in this study. We assessed the association between clinical characteristics, MTX pharmacokinetics, MTX delayed elimination, and adverse events, including hepatotoxicity, acute kidney injury (AKI), and myelosuppression. RESULTS AND DISCUSSION: A total of 124 adverse events occurred after MTX infusion. Using independent sample t-tests, we found that patients with myelosuppression had higher MTX area under the concentration-time curve up to 48 h after infusion (AUC0-48h ) (p = 0.001) and MTX peak concentration (Cmax ) (p = 0.002). MTX concentrations at 48 and 72 h were higher in patients with AKI than in those without (p = 0.034 and p = 0.041, respectively). Using chi-square tests, we found that AKI was correlated with MTX elimination at either 48 h or 72 h (22.1% vs. 8.2%, p = 0.010). By multivariate logistic regression model, our results showed that baseline level of ALT and WBC had a significant effect on hepatotoxicity (OR = 1.079, 95% CI 1.044-1.116, p = 6.9 × 10-6 ; OR = 0.808, 95% CI 0.711-0.917, p = 0.001, respectively). Patient's age, eGFR before MTX infusion, and co-administration of vindesine had a significant effect on AKI (OR = 0.960, 95% CI 0.935-0.986, p = 0.003; OR = 1.009, 95% CI 1.001-1.017, p = 0.034; OR = 5.463, 95% CI 1.793-16.646, p = 0.003, respectively). LDH and Co-administration of vindesine had a significant effect on myelosuppression (OR = 0.985, 95% CI 0.972-0.998, p = 0.025; OR = 3.070, 95% CI 1.032-9.133, p = 0.044). WHAT IS NEW AND CONCLUSION: Our study demonstrated that co-administration of VDS, eGFR before MTX infusion, and the baseline index of laboratory examinations including ALT, WBC, LDH may be useful biomarkers for predicting MTX-induced toxicities.


Assuntos
Injúria Renal Aguda , Doença Hepática Induzida por Substâncias e Drogas , Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos , Linfoma , Humanos , Metotrexato/efeitos adversos , Antimetabólitos Antineoplásicos/efeitos adversos , Vindesina , Injúria Renal Aguda/induzido quimicamente , Fatores de Risco , Doença Hepática Induzida por Substâncias e Drogas/etiologia , Sistema Nervoso Central , Linfoma/tratamento farmacológico
5.
ACS Appl Mater Interfaces ; 14(10): 12234-12242, 2022 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-35234035

RESUMO

Prussian blue analogues (PBAs) are considered one of the promising cathodes for sodium-ion batteries because of their low cost and tunable structure. As an intrinsic characteristic, the influence of structured water in PBAs on the electrochemical properties is still controversial. Herein, low-vacancy iron hexacyanoferrate with different interstitial water contents is synthesized through the citric acid-assisted single iron source method. Ex situ Fourier transform infrared and X-ray diffraction characterization reveals that the interstitial water can stably exist in the Prussian blue framework during repeated cycling. The long-standing interstitial water can reduce the volume change during the Na+ insertion/extraction process, resulting in improved cycling stability. Thanks to the low Fe(CN)64- vacancies and pillar role of interstitial water in the crystal framework, the HW-PB exhibits a high reversible capacity of 117 mAh g-1 and excellent long cycle performance with a capacity retention of 91% after 1380 cycles. This work broadens the understanding of the relationship between the interstitial water in PBAs and Na-storage performances, providing guidance for the precise synthesis of high-quality PBAs.

6.
Medicine (Baltimore) ; 101(2): e28320, 2022 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-35029175

RESUMO

ABSTRACT: Developmental dysplasia of the hip (DDH) is common among Chinese infants, but a lack of large-scale, multi-center epidemiological studies has made it difficult to characterize the risk factors associated with this disease.This multi-center cohort study included 19,833 Chinese infants aged 14 days to 6 months. A multi-center ultrasound protocol was used to diagnose hip abnormalities, and epidemiological data of the infants were collected through questionnaires. Categorical variables were expressed as percentages and compared using χ2 test. Multivariate analysis was performed through logistic regression.Of 19,833 infants, 345 had DDH (1.7%). DDH incidence was higher in female infants (n = 279) than in male infants (n = 66) (χ2 = 95.89, P < .05), and there were more left hip cases (n = 149) than right hip cases (n = 79) (χ2 = 12.49, P < .05). DDH incidence was statistically different amongst different age groups in months (χ2 = 451.71, P < .05), and it gradually decreased with age (P < .05). The prevalence of a positive DDH family history, breech presentation, oligohydramnios, swaddling style, and other musculoskeletal deformities was higher in the positive group than in the negative group (all P < .05). No significant differences were found in terms of delivery by cesarean section, multiple births, or premature birth between both groups.Family history, breech presentation, oligohydramnios, musculoskeletal deformities, and female sex are high-risk factors for DDH in Chinese infants. The incidence of DDH gradually decreases with age. The results of this study provide evidence for the epidemiology of infant DDH in China.


Assuntos
Displasia do Desenvolvimento do Quadril , Povo Asiático , Apresentação Pélvica , Cesárea , China , Displasia do Desenvolvimento do Quadril/diagnóstico por imagem , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Oligo-Hidrâmnio , Gravidez , Estudos Retrospectivos , Fatores de Risco , Ultrassonografia
7.
Front Pharmacol ; 10: 1447, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31866865

RESUMO

Background and Objective: Intravenous contrast-enhanced ultrasound (CEUS), using the second-generation ultrasound contrast agent SonoVue®, has been widely used in adults. In 2016, it was approved for pediatric applications by the American Food and Drug Administration (FDA). However, it has not been approved by the Chinese Food and Drug Administration (CFDA). The objective of the study was to evaluate the safety and effectiveness of CEUS in children prospectively at a single center in China. Methods: A total of 312 cases of Chinese children were enrolled in clinical trials. Contrast agent was given intravenously with two different doses, including 2.4 ml/time and 0.03 ml/kg. All CEUS was performed for evaluating adverse effect and the diagnostic accuracy compared with the pathology and enhanced CT. Results: All 312 subjects underwent CEUS successfully. The dose of contrast agent for CEUS was 2.4 ml between November 2015 and June 2016, which was modified to 0.03 ml/kg between July 2016 and April 2019, according to the recommendation of the FDA. With the two different doses of the contrast agent, the heart rate, respiration rate, oxygen saturation, and blood pressure of the participants had no statistically significant difference (P > 0.05) before and after administration. The blood pressure had been significantly decreased in participants who received combined anesthetic administration. Following 600 intravenous injections of the CEUS, there were three cases of transient rash and three cases of hypotension (n = 6, 1.92%). The six recovered quickly after receiving intravenous methylprednisolone and epinephrine. Most of the studies were performed for evaluating renal microcirculation and assisting renal biopsy (192/312 [61.5%]), which together had a 98.9% effectiveness in the identification of pathology in the specimens. Some studies were conducted to identify a mass in the liver, retroperitoneum, abdominal cavity, kidneys, testicles, thyroid, and so on (99/312 [31.4%]), which had a 97.6% accuracy. The other studies were conducted to identify trauma, vascular malformation, infection, hemorrhage, and so on (21/312 [6.73%]), which had a similar accuracy to enhanced CT. Conclusion: The adverse effects of CEUS in children are similar to that in adults. The results indicate that it is safe to use SonoVue® for CEUS in pediatric patients.

9.
Zhonghua Zheng Xing Wai Ke Za Zhi ; 18(5): 285-7, 2002 Sep.
Artigo em Chinês | MEDLINE | ID: mdl-12471819

RESUMO

OBJECTIVE: In search of a simpler and safer technique for auricular reconstruction with good appearance. METHODS: Medpor implant was used as auricular framework, and covered by temporal fascia flap and skin graft. RESULTS: Ear reconstruction was successfully achieved in 19 cases, the newly formed ears all had good appearance after edema disappeared 1 or 2 months postoperatively. CONCLUSION: Medpor is a kind of good implant material because it is steady in nature, easy to be sculptured. Temporal fascia flap is rich in blood supply, tough and tensile in biomechanics. So the combination of Medpor implant framework with temporal fascia flap is preferable in auricular reconstruction.


Assuntos
Orelha Externa/cirurgia , Procedimentos de Cirurgia Plástica/métodos , Próteses e Implantes , Retalhos Cirúrgicos , Adolescente , Adulto , Criança , Pré-Escolar , Orelha Externa/anormalidades , Fascia Lata/cirurgia , Feminino , Humanos , Masculino , Polietilenos , Retalhos Cirúrgicos/irrigação sanguínea , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA